NTTP Series|Thunder Endurance Transformer|PRODUCTS|Tokyo Rikosha co.,Ltd

PRODUCTS

Thunder Endurance Transformer NTTP Series Various of a Transformer

NTTP Series

Specifications
The Thunder Endurance Transformers is intended to protect an equipment and a human body which occur abnormal voltage from the thunder and an electrical line accident.
Characteristics
The shock boom voltage tolerated dose 30KV(1.2×50μS). Surge transition modulus is less than1/1000(-60db).  
ETC
Three phase built in type

Product Specifications

Thunder Endurance Transformer

TYPE NSTP NSTR NTTP NTTR
Installation externals Built in type No case Setup type with case Built in type No case Setup type with case
Phase Single Phase Single Phase 3Phase 3Phase
Line Type 2 Line 2 Line 3 Line 3 Line
Frequency 50/60Hz 50/60Hz 50/60Hz 50/60Hz
Constant Input Voltage 100 - 400V(It depends on specification.) 100 - 400V(It depends on specification.) 100 - 400V(It depends on specification.) 100 - 400V(It depends on specification.)
Constant Output Voltage 100 - 400V(It depends on specification.) 100 - 400V(It depends on specification.) 100 - 400V(It depends on specification.) 100 - 400V(It depends on specification.)
Output capacity 500 - 10KVA(It depends on specification.) 500 - 10KVA(It depends on specification.) 5 - 50KVA(It depends on specification.) 5 - 50KVA(It depends on specification.)
Heat-resisting class H
H
H
H
Surge Transfer Rate(equilibrium) Less than -60 db (3KV 1.2×50μS) Less than -60 db (3KV 1.2×50μS) Less than -60 db (3KV 1.2×50μS) Less than -60 db (3KV 1.2×50μS)
Impulse Voltage Endurance Primary-Secondary - Groundings 30KV (1.2×50μS not including Arrester) Primary-Secondary - Groundings 30KV (1.2×50μS not including Arrester) Primary-Secondary - Groundings 30KV (1.2×50μS not including Arrester) Primary-Secondary - Groundings 30KV (1.2×50μS not including Arrester)
Efficiency More than 90% less than 5KVA more than 5KVA more than 95% More than 90% less than 5KVA more than 5KVA more than 95% More than 90% less than 5KVA more than 5KVA more than 95% More than 90% less than 5KVA more than 5KVA more than 95%
Insulation Voltage Endurance Over 100MΩ at DC1000V megger Over 100MΩ at DC1000V megger Over 100MΩ at DC1000V megger Over 100MΩ at DC1000V megger
Insulation Voltage Endurance Primary-Secondary - Groundings AC1000V (1min. not including Arrester) Primary-Secondary - Groundings AC1000V (1min. not including Arrester) Primary-Secondary - Groundings AC1000V (1min. not including Arrester) Primary-Secondary - Groundings AC1000V (1min. not including Arrester)

NTTPType 3Phase Built in type No case

Type Output capacity
KVA
Size
WDH
Mass Kg
NTTP-5K 5K 400×200×370 55
NTTP-10K 10K 430×270×430 90
NTTP-15K 15K 440×290×460 115
NTTP-20K 20K 460×300×460 130
NTTP-30K 30K 500×300×550 170
NTTP-50K 50K 580×360×550 250

Click here to order catalog